Caddx Installer Manual
. Programming Worksheets.37-50 SIA and Contact ID Formats.
2 RANGER 8980 INSTALLATION MANUAL General Description The Caddx Ranger 8980 is a versatile 8 zone up/downloadable security control with a built -in digital communicator. This is the NX-8E Control Panel Installation Manual. This document includes an overview of the product and detailed instructions explaining how to install the NX. You do this by referring to pages 16 and 17 of the Installation Manual where there's a. For the purpose of this guide my system's hardwire zones will be.
51-52 Expander Trouble Reporting Information.53 Wiring Diagram.54 Terminal Description.55 Telephone Interface Information.56 CE Notice / Declaration.57 Underwriters Laboratories Information.58 Specifications.Back GE Interlogix Gladewater, Texas 1-800-727-2339. GENERAL DESCRIPTION The NetworX NX-8 represents a new approach to security systems design. Drawing on our experience in the world market as the largest exporter of USA manufactured controls, we have developed the most flexible, durable, and user- friendly control ever seen in our industry. Featuring sophisticated software which allows up to 99 users to interface with 48 zones, 8 partitions, and a host of integrated fire, access, verification, and input/output modules, all reported with the most comprehensive and fast SIA and Contact ID formats. FEATURE DEFINITIONS Abort - If enabled, the NX-8 will wait the programmed number of seconds in location 40 prior to sending an alarm.
During this delay time, the 'Cancel' LED will flash. To abort the report, type in a code and press the Cancel key. The LED will extinguish. Cancel - If enabled, the NX-8 will send a 'Cancel' report if when the system is disarmed and the Cancel button is pressed within 5 minutes of an alarm. Once the Cancel key is pressed, the 'Cancel' LED will illuminate until the central station acknowledges the 'Cancel'. Group Bypass - A designated group of zones can be programmed to bypass by pressing Bypass- 0-Bypass- Bypass prior to arming. (See locations 111-149, pages 33-36) NOTE: For UL installations, this feature shall be disabled.
Immediate Restore By Zone- The NX-8 can be programmed to send alarm and restore reports as soon as they occur, or wait until the siren time has expired. Siren Blast For Arming- The NX-8 can be programmed to give a one second siren blast when the panel is armed, at the end of the exit delay, or when the central station receiver acknowledges the closing report. It can also give one blast for remote (keyswitch) arming and two blasts for remote disarming. PROGRAMMING THE NX-8 LED KEYPADS This section describes how to program the address and partition of each keypad as well as the options that are available.
The address of the keypad is important because this is how the panel supervises the keypads. The factory default for the Master code is 1-2-3-4 when using a 4-digit code or 1-2-3-4-5-6 for a 6-digit code. CHANGING USER CODES: 1) Enter r-5-master code - The 'Ready' LED will flash. 2) Enter the 2 digit user number (always 2 digits such as '03' for user 3) - The 'Ready' LED will illuminate steady. 3) Enter the new user code designated for that individual - The 'Ready' LED will flash indicating that the code was accepted. PROGRAMMING THE NX-8 CONTROL ENTERING THE PROGRAM MODE: To enter the Program Mode, press r-8.
At this time, the five function LEDs (Stay, Chime, Exit, Bypass, & Cancel) will begin to flash. Next, enter the 'Go To Program Code' (FACTORY DEFAULT IS 9-7-1-3). PROGRAMMING EXAMPLE TO BE INSERTED HERE. FEATURE SELECTION DATA: Feature selection data will display the current condition (on or off) of eight features associated with the programming location and segment selected.
Pressing a button on the touchpad (1 thru 8) that corresponds to the 'feature number' within a segment, will toggle (on/off) that feature. Pressing any numeric key between 1 and 8 for selection of a feature, will make the corresponding LED illuminate (feature ON). Segment 2- Phone #1 Backup Control: Programming a '0' in Segment 2 of this location will cause the NX-8 to make the designated number of attempts to Phone #2 before setting the 'Fail To Communicate' condition and stop reporting.
Programming a '1' in this segment will cause the NX-8 to stop trying to communicate after the designated number of attempts have been made to Phone #1. Segment 2: 1 = Zone and Box Tamper and Tamper Restore. 2 = Auxiliary Power Overcurrent, Ground Fault, and Restore for both. 3 = Wireless Sensor Missing and Restore.
Caddx Keypad Installation Manual
4 = Wireless Sensor Low Battery and Restore. 5 = Expander Trouble and Restore.
6 = Fail To Communicate. REPORTING EVENTS TO PHONE NUMBER 2 Phone #2 can be used to back up Phone #1 or for a second receiver to multi-report or split report events. Phone #2 has two programming locations that are used to select which events are reported to this phone number. Location 10 is used to select which events are reported to Phone #2, and location 11 is used to select which partitions are reported to Phone #2. LOCATION 15 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE #3 (2 segments, numerical data) Segment 1, Dial Attempts: Segment 1 of Location 15 is used to enter the number of dial attempts (1 to 15 attempts) the communicator will try to Phone #3 before ending the notification process.
Factory default is '8' and the communicator will make the same number of attempts as those programmed in location 3. LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (See locations 2, 8, &14) Segment 1: 1 = On for 1800hz transmit; Off for 1900hz. 2= On for 2300hz handshake; Off for 1400hz. 3= On for cksum parity; Off for double round parity. 4= On for 2 digit event code. LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (3 segments, feature selection data) Location 23 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system.
In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled by partition. DEFAULT ZONE TYPES (Configurations) Zones can be programmed to be one of twenty different zone types (configurations). Zone types # 17 - 20 can be used for wireless or hardwired zones using European double EOL configuration.
The default zone types are listed below. NOTE: To “null” a zone, program the zone in “Partition Select” as zero (0) in all partitions and do not use end-of-line resistors.
LOCATION 25 - ZONES 1-8 ZONE TYPE (8 segments, numerical data) Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8. Default Zone Types are found in the table on page 18. LOCATION 31 - ZONES 25-32 ZONE TYPE GROUP (8 segments, numerical data) Location 31 contains the Zone Type for zones 25-32.
Segment 1 is for zone 25, Segment 8 is for zone 32. Default Zone Types are found in the table on page 18. To customize a Zone Type, see page 33.
LOCATION 32 - PARTITION SELECT, ZONES 25-32 (8 segments, feature selection data) Location 32 is used to select the partition(s) that zones 25-32 reside in. LOCATION 37 - SIREN AND SYSTEM SUPERVISION (5 segments, feature selection data) Location 37 is used to enable various system feature and reporting options.
(Refer to the feature definitions.) Segment 1: 1 - On if siren sounds for 'Telephone Line Cut' when armed. 2 - On if siren sounds for 'Telephone Line Cut'. LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data) Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the Dynamic Battery Test to be 30 minutes, you should program 3-0-r in segment 1 of this location. The 3-0 is the number of minutes, and the r stores the data and moves to the next segment of this location. Location 44 contains the 'Duress' code.
This Location contains either 4 or 6 digits. If the 6-digit code option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not enabled in location 41, the last 2 digits will be ignored. AUXILIARY OUTPUT EVENT SELECTION DATA EVENT DATA EVENT Burglary Alarm Fire Trouble Fire Alarm Chime 24 Hour Alarm Expander Trouble Trouble Alarm Dynamic Battery Test Time Tamper Alarm Open Period Yelping Siren (Burglary) Closed Period Temporal Siren (Fire) Listen-In Any Siren Line Seizure Any Bypass Ground Start.
LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data) Program a '1' if the interval is to be in hours; Program a '0' if in days. Add a A2' to suppress the daily Segment 1: test or a A3' to suppress the hourly test if any report has been sent. Segment 2: Program the Autotest interval from 1-255 hours/days.
LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS. LOCATION 56- RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data) Location 56 contains the event code for any zone 'Restore'. LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data ) Location 59 contains the event code for a zone 'Trouble' for a 4+2 format.
The digit programmed in this location will be sent as the tens digit. The zone ID will always be reported as the zone number (i.e. 9 for zone 29).
Any segment left as '0'. LOCATION 65 - KEYPAD PANIC COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data) Location 65 contains the tens and ones digits that will be sent for a 4+2 format if the keypad 'Panic' is enabled in the partition feature selection Segment 1 contains the tens digit segment 2 contains the ones digit. LOCATION 66 - KEYPAD MULTIPLE CODE ENTRY TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data) Location 66 contains the tens and ones digits that will be sent for a 4+2 format if the keypad 'Multiple Code Entry'. LOCATION 74 - EXPANDER TROUBLE AND EXPANDER TROUBLE RESTORE COMMUNICATOR CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data) Location 74 contains the tens and ones digits for a 4+2 format that will be sent if 'Expander Trouble Reporting' is enabled. LOCATION 81 - START PROGRAM AND END PROGRAM COMMUNICATOR CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data) Location 81 contains the tens and ones digits for a 4+2 format that will be sent if 'Start / End Programming Reporting' is enabled.
LOCATION 93 - PARTITION 3 FEATURE AND REPORTING SELECTIONS (3 segments, feature selection data) Location 93 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system. In addition, certain communicator reports are enabled in this location. Each of these features can be enabled by partition. LOCATION 101 - ACCOUNT CODE FOR PARTITION 6 (6 segments, numerical data) The account code sent when partition 6 is reported is programmed in location 101.
If location 101 is left unprogrammed (all A10' ) then the account code corresponding to the Phone number dialed will be used. Program the account code is less than six digits, program a A10'. LOCATION 109 - PARTITION 8 ENTRY EXIT TIMERS (4 segments, numerical data) Location 109 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times.
Valid entries are 10-255 seconds. If all segments are A0', the entry and exit times for partition 1 will be used. Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
LOCATION 115 - ZONE TYPE 3 CHARACTERISTIC SELECT (3 segments, feature selection data) Use 'Zone Type Characteristic Selections' described in Location 111, page 33. LOCATION 116 - ZONE TYPE 4 ALARM EVENT CODE (1 segment, numerical data) Location 116 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on page 52. LOCATION 129 - ZONE TYPE 10 CHARACTERISTIC SELECT (3 segments, feature selection data) Use 'Zone Type Characteristic Selections' described in Location 111, page 33. LOCATION 130 - ZONE TYPE 11 ALARM EVENT CODE (1 segment, numerical data) Location 130 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on page 52. LOCATION 142 - ZONE TYPE 17 ALARM EVENT CODE (1 segment, numerical data) Location 142 contains the event code sent for a Contact ID or SIA report.
The desired event code should be chosen from the list on page 52. The zone ID will be that zone that is in alarm.
If 4+2 format is being used, the number programmed in this location will be sent as the tens digit. NX-8 PROGRAMMING WORKSHEETS (Factory defaults for segments are in bold italics text and 'Quick Start' locations are identified with the symbol.) DESCRIPTION DEFAULT PROGRAMMING DATA 11 PHONE #1 14-14-14-14-14-14-14-14-14-14- 14-14-14-14-14-14-14-14-14-14 11 PHONE #1, ACCOUNT CODE 10 - 10 - 10 - 10 - 10 - 10. DESCRIPTION DEFAULT PROGRAMMING DATA PHONE #2, SELECTING WHICH PARTITIONS REPORT TO PHONE #2 Segment #1 (Circle Numbers To Program) Partition #1 Partition #2 Partition #3 Partition #4 Partition #5 Partition #6 Partition #7 Partition #8 14 PHONE #3 14-14-14-14-14-14-14-14-14-14- 14-14-14-14-14-14-14-14-14-14.
DESCRIPTION DEFAULT PROGRAMMING DATA 16 DOWNLOAD ACCESS CODE 8-4-8-0-0-0-0-0 16 RINGS TO ANSWER DOWNLOAD DOWNLOAD CONTROL Segment #1 (Circle Numbers To Program) Enables two call answering machine defeat Enables tone sniff answering machine defeat Requires callback before downloading Shutdown control panel Lock out local programming. DESCRIPTION DEFAULT PROGRAMMING DATA ZONES 9-16, ZONE TYPES 6-6-6-6-6-6-6-6 ZONES 9-16, PARTITION SELECTION (Segment 1=Zone 9 thru Segment 8=Zone 16) Segments Partition #1 Partition #2 Partition #3 Partition #4 Partition #5 Partition #6 Partition #7 Partition #8 ZONES 17-24, ZONE TYPES. DESCRIPTION DEFAULT PROGRAMMING DATA ZONES 41-48, ZONE TYPES 6-6-6-6-6-6-6-6 ZONES 41-48, PARTITION SELECTION (Segment 1=Zone 41 thru Segment 8=Zone 48) Segments Partition #1 Partition #2 Partition #3 Partition #4 Partition #5 Partition #6 Partition #7 Partition #8 SIREN AND SYSTEM SUPERVISION. DESCRIPTION DEFAULT DATA Segment #5 (Circle numbers to program) Lost Clock service LED enable.
Zone Doubling enable. Disable on-board eight zones. Enables two trips on the same cross-zone to activate the alarm. Disables bypass reports for force armed zones Silent exit. Clock uses internal crystal. DESCRIPTION DEFAULT DATA GO TO PROGRAM CODE PARTITION AND AUTHORIZATION Segment #1 (Circle numbers to program) Reserved. Enables 'Go To Program Code' as an arm only code.
Enables 'Go To Program Code' as an arm only after closing. Enables 'Go To Program Code' as a master arm/disarm code (can change user codes) Enables 'Go To Program Code'. DESCRIPTION DEFAULT DATA AUTOTEST CONTROL Segment #1: Program a '1' if the interval is hours, a '0' if in days. Add a A2' to suppress the daily test or a A3' to suppress the hourly test.
Segment #2: Program the autotest interval from 1-255 days or hours. Segment #3: Program the autotest report in 24 hour time format. DESCRIPTION DEFAULT DATA BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY Segment #1: Partition #1 Bypass code Segment #2: Partition #2 Bypass code Segment #3: Partition #3 Bypass code Segment #4: Partition #4 Bypass code Segment #5: Partition #5 Bypass code Segment #6: Partition #6 Bypass code Segment #7: Partition #7 Bypass code Segment #8: Partition #8 Bypass code. DESCRIPTION DEFAULT DATA COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY DURESS AUXILIARY 1 AUXILIARY 2 KEYPAD PANIC KEYPAD MULTIPLE CODE ENTRY TAMPER BOX TAMPER / BOX TAMPER RESTORE 0-0-0-0 AC FAIL / AC RESTORE 0-0-0-0 LOW BATTERY / LOW BATTERY RESTORE 0-0-0-0. DESCRIPTION DEFAULT DATA PARTITION 2, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 Quick Arm LED Extinguish enable Open/Close Re-Exit Require user code for bypassing Bypass Auto Bypass zones Restore Silent Panic Bypass sounder alert Trouble Audible Panic AC Power/Low Battery sounder alert Tamper Auxiliary 1.
DESCRIPTION DEFAULT DATA PARTITION 5, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 Quick Arm LED Extinguish enable Open/Close Re-Exit Require user code for bypassing zones Bypass Auto Bypass Bypass sounder alert Restore Silent Panic AC Power/Low Battery sounder alert Trouble Audible Panic Enables Bypass toggle. DESCRIPTION DEFAULT DATA PARTITION 8, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 Quick Arm LED Extinguish enable Open/Close Re-Exit Require user code for bypassing zones Bypass Auto Bypass Bypass sounder alert Restore Silent Panic AC Power/Low Battery sounder alert Trouble Audible Panic Enables Bypass toggle. ZONE TYPE 8 CHARACTERISTIC SELECT 1-13-378 ZONE TYPE 9 ALARM EVENT CODE ZONE TYPE 9 CHARACTERISTIC SELECT 6-1245-5678 ZONE TYPE 10 ALARM EVENT CODE ZONE TYPE 10 CHARACTERISTIC SELECT 24-5-78 ZONE TYPE 11 ALARM EVENT CODE ZONE TYPE 11 CHARACTERISTIC SELECT 3-0-0 ZONE TYPE 12 ALARM EVENT CODE ZONE TYPE 12 CHARACTERISTIC SELECT.
APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA The table below list the event codes sent for the following reports (if enabled) when using CONTACT ID or SIA formats. REPORT CONTACT ID MANUAL TEST AUTOTEST OPEN (user number) CLOSE (user number) CANCEL (user number) DOWNLOAD COMPLETE. APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-8 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come from the chart below and be programmed in the zone type event code. APPENDIX 3 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables below list the device numbers that will be reported for trouble conditions.
Device Device # reported NX-8 Control Panel See page 52 for possible report codes. NX-534E Two Way Listen-In NX-540E “Operator”. NX-8 WIRING DIAGRAM For CE labeled products, please refer to page 57 for specific electrical requirements. TERMINAL DESCRIPTION TERMINAL DESCRIPTION House Telephone Ring (Grey).
Telephone Ring (Red). Telephone Tip (Green). House Telephone Tip (Brown). EARTH Earth Ground.
Connect to a cold water pipe or a 6 to 10 foot driven rod. Connect to a 16.5V 25, 40 or 50 VA Class ll U.L. Approved transformer. If used as a siren output(default), the speaker rating should be 15 watt at 8 or 16 ohm, or 30/40 watt at 4, 8, or 16 ohms.
LOCAL TELEPHONE COMPANY INTERFACE INFORMATION TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and standard telephone company provided jacks or equivalent in such a manner as to allow for immediate disconnection of the terminal equipment. NOTICES (Applies to products which have the CE mark attached) Declaration of Conformity Network Compatibility Declaration We declare under our sole responsibility that this Manufacturer’s Name: Caddx Controls product is designed to work with the networks in the Manufacturer’s Address: 1420 North Main Street countries marked with a check ( ) and may have Gladewater TX 75647 interworking problems with the countries that are not. UNDERWRITERS LABORATORIES INFORMATION The NetworX NX-8 holds the following listings from Underwriters Laboratories (US and Canadian): Household Burglary (UL1023) (ORD-C1023-1974) Household Fire (UL985) (CAN/ULC S545-M89) Local Grade A Mercantile, Police Station Connect with Basic Line Security (UL609) (requires #NX-003-C enclosure) (CAN/ULC S303-M91) Grade B &. BOARD INSTALLATION Inside the can, several 2-holed insertion points have been constructed.
This allows for either vertical or horizontal placement of the modules. Notice that each insertion point has two sizes of holes - a larger hole and a smaller hole. Diagram 1: The black plastic PCB guides are grooved on one edge where the PC board will be seated. SYSTEM NOTES Page 60. SPECIFICATIONS OPERATING POWER 16.5 VAC 25, 40, or 50 VA Transformer AUXILIARY POWER w/25 VA Transformer 12 VDC Regulated 500 mA w/40 or 50 VA Transformer 12 VDC Regulated 1 AMP w/NX-320 Power Supply 12 VDC Regulated 2 AMPS + Control Panel Power LOOP RESISTANCE Standard Loop.